- DOWNLOAD PDF
-
SECTION 13125 -PERMANENT GRANDSTANDS
PART I -GENERAL
1.01 SYSTEM DESCRIPTION
A. Provide design, labor, material, equipment and supervision necessary
to complete installation of Permanent steel grandstand, including
the following:
1. Steel Substructure
2. Decking System
3. Concrete Foundation
4. Press-Box Support Structure
5. Press-Box
6. Ramps and Stairs
1.02 QUALITY ASSURANCE
A. Manufacturer Qualifications: Manufacturers
must have five years of experience in the manufacture of bleachers
and grandstands; welders must be AWS certified; manufacturing capability
according to various code compliances.
B. Installer Qualifications: Factory-trained and
experienced in the proper installation of grandstands.
C. Source Quality Control: Mill Test Certification.
1.03 SUBMITTALS
A. Manufacturer's Product Data: Submit manufacturer's
descriptive product data for project.
B. Shop Drawings: Manufacturer to submit shop drawings
and design calculations sealed by a registered professional engineer
in the State of the project and schedules for type, location, quantity,
and details of steel and aluminum components required for project.
Submittal of calculations is for determining compliance with specifications
and will not be a review of calculations. The submittal does not
relieve contractor and engineer from responsibility.
C. Product Sample: Submit one 18-inch seat sample.
1.04 SITE CONDITIONS
A. Owner will verify site location.
B. Owner will locate all underground utilities
and obstructions.
C. Owner will furnish geotechnical report indicating
soil conditions and allowable soil bearing pressure.
D. Owner will verify grandstand location and benchmark
dimensions and elevation.
1.05 BUILDING CODES
A. Codes and Standards: Design, fabrication, and
installation shall be in accordance with applicable codes, regulations,
and accessibility requirements(ADA). Owner will furnish local code
requirements.
1.06 WARRANTY
A. Permanent Grandstand shall be under warranty
for a period of one year beginning at Date of Substantial Completion
for Projects installed by Manufacturer. The Grandstand is warranted
to be free from defect in materials and workmanship in the course
of manufacture. This warranty excludes defects resulting from abnormal
use in service, accidental or intentional damage, or any occurrences
beyond Manufacturer's control.
1.07 MAINTENANCE
A. Owner will conduct inspections and required
maintenance of grandstand to assure safe conditions.
Contractor shall instruct Owner's maintenance personnel on inspecting
the grandstand and provide detailed instruction of how to inspect
and maintain the structure.
PART 2 -PRODUCTS
2.01 ACCEPTABLE MANUFACTURERS
A. The design for the bleacher seating grandstands
is based on designs by
Southeastern Seating, Tampa Florida, 800-248-2099
Other manufacturers seeking to be approved must submit product literature
on horizontal beam design to the Owner for review and receive approval
from Owner seven days prior to bid date.
Site visitation is required prior to bidding this project. Any
problems with the site or design that could have been forseen by
a site visitation are the responsibility of the contractor.
2.02 PERMANENT STEEL GRANDSTAND
A. Product Description
1. Horizontal Beam Design as shown in drawings.
a. Horizontal Beam Design: Columns placement per contract drawings.
All
horizontal beams are hot rolled wide flange beams. Traverse bays
are free
of cross bracing at exit ramps, stairs and walkways.
B. Stringers: Stringers are hot rolled wide flange
with angle rise and
depth fabrication and are placed at 6 feet on center.
C. Front Cross Aisle:
1) Clear width 72" inches.
2) Elevated above grade as shown on drawings.
D . Entry stairs to be firmly anchored to uniformly
poured concrete bases.
1) Stair rise: 6 inches per International Building Code,
2) Stair tread depth: 11 inches per International Building Code.
3) Guardrails on Stair to be 34 inches above leading edge of step
with
intermediate rail spacing at 6 inches.
4) Optional: Stairs to have handrail extension. The handgrip portion
of
handrails shall not be less than 1 1/2 inches or more than 2 inches
in
cross-sectional dimension or the shape shall provide an equivalent
gripping surface. The handgrip portion of handrails shall have a
smooth
surface with no sharp comer. The top of handrails and handrail
extensions shall be placed not less than 34 inches or more than
38
inches above the nosing of treads and landings.
Handrails shall be continuous the full length of the stairs and
shall
extend in the direction of the stair run not less than 12 inches
beyond
the bottom riser.
E. Aisles:
1) Aisles with seating on both sides to have 34-inch high handrail
with
intermediate rail at approximately 22 inches above tread.
2) Handrails with rounded ends are discontinuous to allow access
to seating
through a space 22 inches (min.) to 28 inches (Max.).
F. Decking:
1) Rise per row SEE DRAWINGS
Depth per row SEE DRAWINGS
2) Each seat 17 inches above its respective tread.
3) Decking Arrangement: SEE DRAWINGS
G . Seating Selection:
1. Aluminum Bench Seat to be 2 x 10 nominal
H. Guard railing: To be at all sides of bleacher,
entry stairs and ramps,
portals, and landings. Railing to be anodized aluminum with end
plugs at
ends of straight runs and/or elbows at comer. All guardrails shall
be
secured to angle rail risers by galvanized fasteners. Railing shall
be
42" above walkways and entrances. Railing shall be 42"
above any
adjacent aisle surface. Guard railing on sides and back shall include
VERTICAL ALUMINUM PICKET SAFETY FENCE
I. Ramps:
1) Slope: 12:1.
2) Guardrail to be 42 inches above ramp with intermediate rail spacing
at 4
inches.
3) Lower Ramps at their landings to have handrail extension. The
handgrip
portion of handrails shall not be less than 1 1/2 inches or more
than 2
inches in cross-sectional dimension or the shape shall provide an
equivalent gripping surface. The handgrip portion of handrails shall
have a smooth surface with no sharp comers. The top of handrails
and
handrail extensions shall be placed not less than 34 inches or more
than
38 inches above the ramp or landing surface. Handrails shall be
continuous the full length of the ramp and shall extend in the direction
of the ramp not less than 12 inches beyond the end of the ramp.
J . Handicap Provision:
1) Quantity of wheelchair spaces: As shown in drawing
2) Riser area adjacent to wheelchair spaces to have intermediate
construction so a 4 inch (4") sphere cannot pass through opening.
l. Press Box:
A. Provide steel support structure
B. Materials/Finishes:
1) Substructure: Galvanized steel
2) Extruded Aluminum:
a. Seat Planks: Extruded aluminum alloy, 6063-T6: Clear anodized
b. Tread Planks, Riser Planks: Extruded aluminum alloy, 6063-T6
Mill finish
c. Joint Sleeve Assembly to be inserted in flat plank to maintain
true
alignment in joining together two plank pieces. Extruded aluminum
alloy,
6063-T6, mill finish, Splice cover is unacceptable between two flat
plank pieces joined in a straight line.
3. Accessories:
(1) Bolts, Nuts: Hot-dipped galvanized.
(2) Hold-down Clip Assembly: Aluminum alloy 6061-T6, mill finish.
C. Fabrication:
1. Design Loads:
a. See drawings.
2. All manufactured connections to be shop welded.
a. Manufactured by certified welders conforming to AWS Standards.
PART 3 -EXECUTION
3.01 INSTALLATION
A. All work performed by factory-trained technicians
experienced in bleacher seating installation.
B. Project as per approved shop drawings.
3.02 FIELD QUALITY CONTROL
A. Foundation. Drilled shaft foundations for the
Grandstand shall provide sufficient bearing area at bottom to support
all loads of the grandstand. Depth and design of footings shall
be as shown on the drawings. Hot-dipped galvanized anchor bolts
shall be set by template and shall be embedded in the concrete foundation
as required by manufacturer's design calculations. Concrete shall
attain working strength of 3,000 psi at 28 days.
3.03 CLEAN-UP
A. Clean up all debris caused by work of this
section.
|